Product Code: 2111
The Fluke Calibration 5606 Full Immersion PRT’s (formerly Hart Scientific) are designed to perform in extreme environments
where both the transition junction and the lead wires are required to withstand temperatures covering the entire
operating range of the probe. (“Immersion” in this case simply means exposure to temperatures other than ambient
and does not necessarily refer to the medium to which the PRT and its components are subjected.) Applications where “full immersion” of probe, transition junction, and lead wire is required can include calibration
or validation of sensors used in laboratory or bio freezers, walkin refrigerators, autoclaves, ovens, stability test
chambers, furnaces or incubators. Other applications might include IQ/OQ/PQ qualification procedures, temperature
mapping, or data logging in temperature controlled spaces or environmental chambers. The 5606 is just two inches (50 mm) in length with a sheath diameter of 1/8 inch (3.1 mm). Since it can be fully immersed
over its entire temperature range, you don’t have to worry about calculating minimum immersion depth—immerse the entire probe,
transition junction, and lead wires, in either noncorrosive liquids or dry mediums ranging from -328 to 320°F (-200 to 160°C). The 100W
precision sensing element (alpha = 0.00385) is specially constructed to prevent the ingress of moisture while achieving
calibration accuracies as good as ± 0.05°C. You get both accuracy and flexibility built into a small, durable package. The lead wires of the 5606 are made of single-conductor enameled copper wire which prevents moisture from wicking
to the sensing element as it would if a more common, stranded lead wire were used. The diameter of the lead wire is
no greater than 0.2 mm, making it easy to run lead wires through a freezer door to your readout or transmitter with
effectively zero energy loss. The 5606 has been proven in common heat transfer fluids such as silicone oil, mineral oil,
ethanol, and even liquid nitrogen with no degradation of the transition junction seal or lead wire insulation. If you need longer lead wire than the standard length, call one of our Application Specialists today for a free quote.
They can also help you determine which readout and probe termination are best suited for your application or help you
select the right calibration for your probe.
Dwyer TSW Temperature Switch
Keller LevelRat Submersible Level Transmitter
AEMC K100 & K110 DC/AC MicroProbes
Carlo Gavazzi Type DCB51 Asymmetrical Recycler Timer
Rosemount 1056 Intelligent Four-Wire Transmitter
Accurate Thermal Systems FTBSL6 Fluidized Temperature Bath
GF Signet 9900 Transmitter
YSI 9800 Photometer
Panametrics PanaFlow MV82 Flow Meter
Watlow Cable Heater
CAS CAST-X 500 Circulation Heaters
Intempco DTG53 / DTG54 Digital Temperature Gauge
Rosemount 8705 Flanged Magnetic Flow Meter Sensors
UE Systems Ultraprobe 9000 Ultrasonic Inspection System
Bently Nevada 330525 Velomitor XA Velocity Sensor
Rotronic CP11 Indoor Air Quality Meter