Product Code: 2389
The KEP AMP-1 signal conditioner amplifies the low level signals from a magnetic pickup or flow transmitter by a factor of more than a hundred times
to drive any ratemeter, counter or controller. The unit uses only 30 mA and operates from 11 to 26 VDC. It has a 2.7K pullup resistor
attached to the open collector output and sinks a minimum of 100 mA to less than 1 V from a maximum of 26 VDC. It is mounted
in a rugged 2″ x 3″ metal housing with screw terminals for easy installation. Operating temperature is 32 to 140°F (0 to 60°C). Note: The low voltage line from the magnetic pickup to the AMP-1 should be less than 10 ft. in length, shielded and isolated from
relays, solenoids or other sources of electrical noise (let the output line make the long run). If the input is too sensitive, lower the 1.1K
input impedance by adding a 220 to 1K ohm resistor across TB1, pins 1 and 2, to increase noise immunity. A special version, the AMP1-10k, is available with 10 kΩ impedance for use with turbine and paddle wheel flowmeters.
Danatronics EHC-09 Ultrasonic Thickness Gauge
E+H Liquiline M CM42 Transmitter
Emerson PACSystems RXi Web Panel
Hedland Flow Meter for Petroleum Fluids
Rosemount Model 1057 Multi-Parameter Analyzer
Druck PV211 Pneumatic Hand Pump
Extech 461825 Photo Tachometer / Stroboscope
Eaton FHF Weatherproof ResistTel Hazardous Area Telephone
Rosemount Model 5081 Transmitters
Alliance Sensors Group SC-200 LVDT Transmitter
Bently Nevada 330500 Velomitor Velocity Sensor
Rosemount 499 Series Dissolved Oxygen/Ozone/Chlorine Sensors
Jewell Instruments LSOX Precision Analog Inclinometer
Honeywell E3Point Gas Monitor
SolaHD SDU DC B Series DIN Rail UPS Power Supply
Rosemount Model 5081 Transmitters