Product Code: 2427
The MTL LC30 surge protector protects load cell and weighing system installations from possible malfunctions or damage to individual strain-gauge
bridges or associated electronic instrumentation caused by severe overvoltages or impulse currents on signal cabling. Weighbridges, silos and other product batching/weighing facilities are typically large metal structures, and are exposed to direct lightning strikes.
Protecting the structure from lightning is not in itself sufficient to prevent the secondary damage to associated electronic systems. Individual load
cells and strain-gauge bridge insulation may break down under the abrupt shift in local structural voltage as lightning currents are dissipated to
local ground, thus allowing surge currents to flow through the connecting cable into the various indicators and power supplies situated some distance
away. The connecting cabling can be armored, shielded, or underground and may still be susceptible to surges. Load cells may be damaged by surges, as few transducer manufacturers make more than a token effort at incorporating protection components. Adequate
protection is even more critical with digital load cells, where electronic components and amplifiers are installed right at the point of greatest exposure. Surge protection devices protect the system at the point of installation, therefore a full system is likely to have at least one MTL LC30 device installed
at the weighbridge to protect the load cell(s), and another LC30 in the weighing control cabin to protect the electronics installed there. Fully solid-state, the LC30 clamps incoming surges immediately without causing undue leakage losses under normal conditions. Once the surge has passed, the
device automatically resets to the passive state, allowing normal operations to continue. The advanced protection concept used in the LC30 also eliminates the
expensive additional earthing systems specified by other suppliers, so field installation is very simple indeed. The LC30 can be used in hazardous area applications with appropriate self-generated system documentation as it is non-voltage producing, non-energy storing ‘simple
apparatus’. Our application guide details the steps necessary to achieve an intrinsically safe installation. The LC30 is designed for use in Zone 2/Div2 and
is also suitable for legal metrology applications.
E+H Proline Promass K 10 Coriolis Flow Meter
E+H Proline Promag W 400 Electromagnetic Flow Meter
Kobold DKB Flow Indicator
Bently Nevada 330525 Velomitor XA Velocity Sensor
Additel 226 Multifunction Process Calibrator
MadgeTech HiTemp140 Autoclave Temperature Data Logger
UE Systems Ultraprobe 201 Grease Caddy
Isotech Orion 796 Liquid Bath Calibrator
E+H Commubox FXA195 USB / HART Modem
E+H Deltabar PMD75 Differential Pressure Transmitter
E+H Liquiphant FTL31 Level Switch
AOI Series 1300 Oxygen Analyzer
Druck PV211 Pneumatic Hand Pump
Ametek Jofra ETC Series Temperature Calibrators
GF Signet Portaflow 220 / 330 Ultrasonic Flow Meter
UE Systems Ultraprobe 3000 Ultrasonic Inspection System