Product Code: 1875
The Time Electronics 1010 DC voltage calibrator is a highly stable and accurate mains or battery powered calibrator for applications requiring a
precision voltage source of low internal resistance. With five ranges up to 10V and resolution up to 0.01μV, the 1010 offers a compact and robust
design making it easily portable and well suited to laboratory, field and industrial use. The 1010 can be used for calibration, linearity, and
gains stability measurements on DC amplifiers, digital and electronic voltmeters, data loggers and chart recorders. It’s high 10ppm per hour
stability and very low noise levels are ideal for these types of applications. Voltage outputs for the Time Electronics 1010 are set by selecting the range switch and dialing up the desired value on the thumbwheel switch. Output
polarity may be selected using the normal/off/reverse switch. The calibrator’s output resistance is typically 500mΩ on the 10V, 1V and 0.1V ranges.
The maximum output current that can be drawn on these ranges is limited to 25mA maintaining specification. The lower ranges have an output resistance
of 1Ω and will supply current up to 30mA. The 1010 uses a precision zener diode as a reference source that provides an input to a F.E.T. chopper amplifier system operating in a feedback
stabilized mode. The gain value is determined by a set of precision metal film resistors, selected by the 5-decade thumbwheel switch on the front panel.
The output voltage is variable from 0.01µV to 9.9999V in 5 ranges. For complete reliability, the calibrator range switch employs two contacts in parallel
for each position in case one contact fails, ensuring the calibrator will still function correctly. The 1010 can be powered from mains supply or by the internal rechargeable battery pack. When the calibrator is plugged into the mains supply the internal
batteries will automatically start to recharge. If unplugged from the mains during operation the internal batteries will continue to power the instrument.
Full charge allows 40 hours typical use. The battery condition monitored by a meter on the front panel. The Time Electronics 1010 DC voltage calibrator is fitted with safety terminals that are fully compatible with 4mm shrouded plugs, as well as standard
plugs, bare wires, and spade terminals.
PIE 211 Automated RTD Calibrator
Rosemount 248R Temperature Transmitter
Ashcroft C-600H-45 Duratemp Thermometer
YSI 9800 Photometer
Keller Acculevel Submersible Level Transmitter
Watlow Flange Immersion Heater
Ashcroft A Series Pressure Switches
Extech 380460 Precision Milliohmmeter
Reliability Concepts Digi-Belt Tension Measurement Tool
Druck DPI 104 Calibration Kit
Kanomax 6006 Anemomaster LITE Anemometer
Isotech 989 Blackbody Calibrator
MRU SWG-100 CEM Emission Monitoring System
KROHNE OPTIMASS 6000 Coriolis Mass Flow Meter
Rosemount Model 3900 pH/ORP Sensor
Rotronic HygroFlex5A-Series Advanced Humidity Transmitters